Short answer

A heat pump may blow cool air for a few minutes during a normal defrost cycle. If it keeps blowing cold air, common causes are the thermostat set to COOL or FAN ON, a stuck reversing valve, low refrigerant from a leak, a failed outdoor fan or compressor, or backup heat strips that are not working. Heavy ice that does not clear is not normal.

Outdoor heat pump unit installed beside a brick home

Step-by-step checks

  1. Check the thermostat mode

    Make sure it is on HEAT and the fan is on AUTO. FAN ON circulates air even when the system is not heating.

  2. Wait out a defrost cycle

    In cold, damp weather the unit runs a defrost cycle for a few minutes. Brief cool air and steam from the outdoor unit are normal.

  3. Look at the outdoor unit

    A thin layer of frost is normal. A thick block of ice, or a fan that is not spinning, is not.

  4. Check the filter and vents

    Restricted airflow makes a heat pump less effective and can cause icing.

  5. Use emergency heat if needed

    If the outdoor unit has clearly failed, EM HEAT keeps the house warm on backup heat until a tech arrives. Expect a higher bill.

  6. Call a technician

    Reversing valves, defrost boards, refrigerant leaks and compressors need a licensed tech.

When to stop and call a pro

Stop troubleshooting and call 📞 (330) 704-6386 if you smell gas or burning, a breaker trips more than once, you see sparks or water near electrical parts, or the problem needs refrigerant or electrical work. Those jobs require a licensed technician.

Related questions

Why is my heat pump blowing cold air in winter?

A short burst of cool air during a defrost cycle is normal. If it continues, likely causes are a stuck reversing valve, low refrigerant from a leak, a failed outdoor fan or compressor, or backup heat strips that are not working.

Is it normal for a heat pump to ice up?

Light frost in cold, damp weather is normal, and the unit should melt it during a defrost cycle that may release steam. A thick block of ice that does not clear points to a defrost control, sensor, airflow or refrigerant problem.

What does emergency heat do on a heat pump?

Emergency heat turns off the outdoor unit and heats the home with backup electric strips or a furnace. Use it only when the outdoor unit has failed, because electric backup heat costs much more to run.