HVAC guide

Why is my HVAC making noise?

Short answer

Most HVAC noises point to a specific part. Buzzing usually means an electrical problem like a failing capacitor or contactor; banging from a furnace can mean delayed ignition; squealing points to a motor or belt; hissing can mean a refrigerant or duct leak; and repeated clicking often means an ignition or relay issue. Loud banging, grinding or burning smells mean turn the system off and call.

Technician connecting service gauges to an AC condenser's refrigerant lines

HVAC noise guide

SoundLikely causeWhat to do
Single click at start or stopNormal relay or thermostat switchingNothing
Rapid, repeated clickingFurnace igniter trying and failing; failing relay or control boardCall for service
Buzzing or humming at the outdoor unitFailing capacitor, stuck contactor, or a motor that can't startTurn off; call. Don't open the panel; capacitors hold a charge
Loud bang or boom when the furnace startsDelayed ignition: gas builds up before lighting; dirty burnersShut off and call. This can crack the heat exchanger
Squealing or screechingWorn blower motor bearings or belt; outdoor fan motorCall soon; motors fail faster once they squeal
Grinding or scrapingFailing motor bearings or something hitting the fanShut off to prevent motor damage
HissingRefrigerant leak (outdoor/indoor coil) or air leak in ductsCall; refrigerant leaks need a licensed tech
Gurgling or bubblingCondensate drain partly clogged or refrigerant flow issueCheck the drain; call if it continues
RattlingLoose panel, screws, debris in the outdoor unit, or ductwork expandingTighten panels; clear debris (power off)
Whistling at vents or returnsRestricted airflow: dirty filter, closed vents, undersized returnsChange filter; open vents

What a contactor and a relay do (and why they buzz)

A contactor is the heavy-duty switch inside the outdoor unit. When the thermostat calls for cooling, a low-voltage signal pulls the contactor closed, sending full power to the compressor and fan. Over time the contacts pit and burn. A worn contactor can buzz, chatter, or stick closed so the outdoor unit runs even when the thermostat is off.

Relays do the same job on a smaller scale inside the furnace or air handler, switching the blower and other parts on and off. A faulty relay or control board can cause clicking without the system starting.

Both are inexpensive parts, but they carry line voltage. Replacing them is a job for a licensed technician.

Noises that mean turn it off now

  • Loud bangs or booms from the furnace at startup
  • Grinding metal, or a screech that keeps getting louder
  • Buzzing with a burning or electrical smell
  • Any noise along with a carbon monoxide alarm. Leave the house and call 911 from outside

More questions

Is it normal for my heat pump to make a whooshing sound in winter?

Yes. During a defrost cycle the reversing valve shifts with a whoosh, the outdoor fan stops, and the unit may release steam. That's normal. Constant loud noise or a unit that never finishes defrosting is not.

Why does my AC hum but not turn on?

A humming outdoor unit with a fan that won't spin usually means a failed run capacitor or a compressor that can't start. Turn it off to avoid overheating the motor and call for service.

Sources